  • NSN-1 Plastic Red PP Cooling Tower Spiral Jet Spray Nozzle New Cooling Tower PP spiral Cone spray nozzle  Spiral nozzles are mainly used for power plants, Coal-burning enterprises, Desulphurization and denitration of electroplating plant, off-gas scrubbing, gas cooling, scrubbing  and sprinkle process,  fire prevention and extinguishments .Spiral nozzle is a kind of conical spray nozzle, commonly used spray Angle is 100-120 degrees, compact spiral nozzle design, can make the liquid in a given size pipeline reach large flow , because of the open channel design, it greatly reducing the nozzle clogging. New plastic PP (polypropylene),one-step injection molding.   Dimension Model NSN   Material PP   Size 1/4", 3/8", 1/2", 3/4", 1"   Common Used Angle 100 - 120 degree   Flow Rate 5.5 to 140L/Min with the pressure 3bar Size Heigt (mm) Screw Diameter (mm) Weight (g) 1/4" 44.5 12.5 2.6 3/8" 49 16 3.5 1/2" 62 20 7.2 3/4" 64 25 10.9 1" 99 32 25.5 PP plastic spiral cone spray nozzles      
  • NSN-02 ABS plastic spray nozzles for cooling Tower Cooling Tower ABS plastic spray nozzles Dimension  Model: NSN-2  connection size  DN20 ( 3/4")  25MM  DN25 (1")  32MM  DN32 (1.2")  40MM  DN40 (1.5")  45MM  DN50 (2")  57MM Features External screw connection Excellent insulation High mechanical strength, resistance of pressure and strong wreckage Excellent resistance of wear Excellent stability and chemical property Resistance of high temperature ABS plastic spray nozzles    
  • ABS Cooling Tower Fan ABS Cooling Tower Fan PVC Cooling Tower Fan Diameter: 500mm, 525m,  560mm, 600mm, 670mm, 700mm, 770mm, 890mm, 970mm, 1150mm, 1500mm.   PVC cooling tower fans are designed by adjustable fan angle, adjust process is as below: 1. using a wrench, loosen the lock screw. 2. grabbing at the fan center, rotating blades to the required Angle by another hand (keep an eye on the blades and fan heart scale); 3. turn the other blades to the same as the first fan scale; 4. lock screw.   ABS Cooling Tower Fan Pictures:    
  • Cooling Tower ABS Sprinkler Head Cooling Tower ABS Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spreaded to cooling tower infill to make sure better cooling effect of the cooling tower.   ABS sprinkler head could make to max. 4 inches, which is usually used in small (below 100 RT) cooling towers. Below is the detailed specification of the ABS material water distribution head:    Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of Aluminium alloy water distribution head for different size. Please make sure external thread or internal thread sprinkler head needed when ordering.
  • Liangchi Cooling Tower Drift Eliminator Liangchi Cooling Tower Drift Eliminator 50mm NEWIN LAD eliminators LAD-50 is a high efficiency cellular drift eliminator and minimize the water drit emission,easy to handle ,lift and remove for inspection and servicing of water dirtribution system hand heat tranfer surface (fill and coil), apply for Liangchi cooling tower and counter flow cooling tower. Feaures ■ Nested sezm modules ■ Minimal pressure drop ■ Optimal droplet capture ■ Maximum operational safety ■ Long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 200 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, LIANGCHI TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   LAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • cooling tower fan motor Round type cooling tower fan motor 5.5kw, 1410r/m, 7.5HP, 4P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
  • cooling tower fan motor Round type cooling tower fan motor 0.18kw, 910r/m, 1/4HP, 6P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
  • Round Type Cooling Tower Reducer Pulley Round Type Cooling Tower Reducer Pulley Round Type Cooling Tower Reducer Specification.         Model Nos.of Groove H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T RT-5 2 45 50 175 76 355 300 263 34 4-Ø13 37 8 RT-6 3 65 60 225 105 456 348 300 38 4-Ø14 41 8 RT-8 4 85 62 265 120 456 428 390 50 6-Ø16 53 12 RT-10 4 85 62 310 135 608 500 450 50 4-Ø16 53 12 RT-12 5 105 62 310 143 660 500 450 60 4-Ø16 63 12 RT-14 6 125 62 320 153 660 500 450 75 6-Ø16 79.5 20  Remark: Above installation data is only for reference. Customization is acceptable  
  • cooling tower fan motor Round type cooling tower fan motor 5.5kw, 1410r/m, 7.5HP, 4P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
  • cooling tower fan motor Round type cooling tower fan motor 0.37kw 910r/m 1/2HP, 6P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
  • Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Mesh Specification: Size: 1800 x 1000 mm or 1600 x 1000 mm (Customization is acceptable) Thickness: 0.6-0.8 mm Wire diameter: 0.5 mm PVC material      Air inlet screen assembly       Air inlet louver sheet picture You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Splash cooling tower fills 850x850mm Splash cooling tower fills 850x850mm Spalsh type cooling tower fills, also called grid fills, it is a type of fills special design for industrial popose cooling tower, such as cooling tower for waste water pricessing, Chemical plant, Tixtile industry etc. Due to the advantages of no-blocking, high strength fills, Its widely used for kinds of dirty water(such as the water contains silt, fiber, oil, etc) processing cooling towers.