Contact Us
  • No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Products
  • Ryoden cross flow cooling tower fills RYH Series 620 x 1080mm Ryoden Cooling tower PVC Fill cooling tower high quality replacement film fills, 3-years quality guarantee. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:     620x 900/1000/1080mm or any Sheet space: 20mm Sheet thickness: 0.30-0.4mm Applicable water temperature: 75℃ ~ -35℃ Applicant: BAC(Batimore aircoil) cross flow square type(box type) cooling tower
  • NS001 Evapco Evajept Nozzle, large orifice-NS001 Evapco Evajept Nozzle, large orifice-NS001 Features:  -Non-corrosive PVC construction with new EvapJet™ nozzles. -Large orifice nozzles prevent clogging and are threaded for easy removal and positive positioning. -66% fewer nozzles. -System branches have threaded end caps to assist with debris removal. Non-corrosive PVC construction with new EvapJet™ nozzles. -Large orifice nozzles prevent clogging and are threaded for easy removal and positive positioning. -66% fewer nozzles! -System branches have threaded end caps to assist with debris removal. Detail pictures Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU Payment term: T/T, L/C, West Union Minimum Order Quantity: 100pcs Newin Other Cooling Tower Nozzles You may be also interested in below cooling tower spray nozzles, please click the nozzle pictures for more details.         
  • Cooling Tower Nylon Sprinkler Head Cooling Tower Nylon Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spread to cooling tower infill to make sure better cooling effect of the cooling tower.   Nylon material sprinkler head could make to max. 4 inches, which is usually used in small (below 100 RT) cooling towers. Below is the detailed specification of the Nylon material water distribution head:  Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of Nylon Sprinkler Head:
  • Direct-connected Planetary Gear Reducer -- NDQ Series Direct-connected Planetary Gear Reducer -- NDQ Series Direct-connected Planetary Gear Reducer -- NDQ Series The speed reducer is a direct-connected planetary gear reducer, adopts a hard tooth surface technology.  Structure is compact, light weight and high torque.           Features - Compact structure, strong overload capacity.   - Light weight and small size.   - Easy installation and maintenance.   Model Description Model Motor Specification Noise Value (JM Distance ) Motor Weight  (KG ) Gear Box  Weight   ( KG ) Reducer  Weight  ( KG ) NDQ 132-4-165 V1  4kw-6(132M1) 67 64 55 119 NDQ 132-4-210 V1  4kw-4(112M)(+) 68 46 55 101 NDQ 132-4-250 V1  4kw-4(112M)(+) 68 46 55 101 NDQ 132-4-320 V1  4kw-4(112M)(+) 68 46 55 101 NDQ 132-5.5-165 V1  5.5kw-6(132M2) 67 75 55 130 NDQ 132-5.5-210 V1  5.5kw-4(132S1) 68 59 55 114 NDQ 132-5.5-250 V1  5.5kw-4(132S1) 68 59 55 114 NDQ 132-5.5-320 V1  5.5kw-4(132S1) 68 59 55 114 NDQ 132-7.5-210 V1  7.5kw-4(132M) 68 72.5 55 127.5 NDQ 132-7.5-250 V1  7.5kw-4(132M) 68 72.5 55 127.5 NDQ 132-7.5-320 V1  7.5kw-4(132M) 68 81 55 136 NDQ 160-11-165 V1  11kw-6(160L) 68 147 83 230 NDQ 160-11-210 V1  11kw-4(160M) 70 107 83 190 NDQ 160-11-250 V1  11kw-4(160M) 70 107 83 190 NDQ 160-11-320 V1  11kw-4(160M) 70 107 83 190 NDQ 160-15-165 V1  15kw-6(180L) 70 190 83 273 NDQ 160-15-210 V1  15kw-4(160L) 70 144 83 227 NDQ 160-15-250 V1  15kw-4(160L) 70 144 83 227 NDQ 160-18.5-210 V1  18.5kw-4(180M) 70 153 83 236 NDQ 160-18.5-250 V1  18.5kw-4(180M) 70 153 83 236 NDQ 160-22-210 V1  22kw-4(180L) 70 170 83 253 NDQ 160-22-250 V1  22kw-4(180L) 68 170 83 253 NDQ 200-15-125 V1  15kw-6(180L) 73 144 148 292 NDQ 200-18.5-165 V1  18.5kw-4(180M) 73 153 148 301 NDQ 200-18.5-210 V1  18.5kw-4(180M) 73 153 148 301 NDQ 200-22-165 V1  22kw-4(180L) 73 170 148 318 NDQ 200-22-210 V1  22kw-4(180L) 73 170 148 318 NDQ 200-22-250 V1  22kw-4(180L) 73 170 148 318 NDQ 200-30-165 V1  30kw-4(200L) 73 228 148 376 NDQ 200-30-210 V1  30kw-4(200L) 73 228 148 376 NDQ 225-37-165 V1  37kw-4(225S) 73 270 148 418 NDQ 225-37-210 V1  37kw-4(225S) 73 270 148 418 NDQ 225-45-165 V1  45kw-4(225M) 73 280 215 495 NDQ 225-45-210 V1  45kw-4(225M) 73 280 215 495   Installation   Model NDQ132 NDQ160 NDQ200 NDQ225 Size A 380 430 490 540 B 340 390 450 500 C 100 100 130 130 D 60 60 80 80 E 14 16 16 16 F 8/10 12/14 14/16 18 G 230 250 340 350 H 17.3/22.3 24.3/27.8 27.8/31.8 34.4 I 28/38 42/48 48/55 60 J 19 19 19 19 K 300 350 400 450 L 265 300 365 400 M 235 272 365 371 N 300 358 405 460 O 209 211 229 249 P 115(1:10) 115(1:10) 115(1:10) 135(1:10) Q 55 60 70 80 R 31.8 34.4 39.9 45.4 S 16 18 20 22 Other types of Gearbox  Click below picture for knowing more details about other seires   
  • Cooling Tower Drift Eliminator Cooling Tower Drift Eliminator 200mm NEWIN SMD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and lose velocity at impact on the blade walls and fall back into the tower. Feaures ■ Made of flame retardant pvc material ■ Maximum drife capture through efficient design ■ Anti-aging, low airflow resistance, high strength ■ Optimal droplet capture ■ easy installation and long service life Specification Model--SMD PVC Max.length depend on customer demand Width depend on customer demand Height 200 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application          Counter flow cooling tower, BAC TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing SMD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for old cooling towers as replacement.    
  • Cross flow cooling tower fills DBH Series 500 x 1200mm Cooling Tower PVC Fills 1200x500 mm , cooling tower fills,  Material: Blue PVC Dimension:     1200x500mm                        1200xany Sheet space: 18 mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • ABS Cooling Tower Fan ABS Cooling Tower Fan ABS & Nylon Cooling Tower Fan Diameter: 550mm, 635mm, 770mm, 890mm, 930mm, 1180mm.   ABS cooling tower fans are designed by adjustable fan angle, adjust process is as below: 1. using a wrench, loosen the lock screw. 2. grabbing at the fan center, rotating blades to the required Angle by another hand (keep an eye on the blades and fan heart scale); 3. turn the other blades to the same as the first fan scale; 4. lock screw.   ABS & Nylon Cooling Tower Fan Pictures:        
  • Cooling Tower ABS Sprinkler Head Cooling Tower ABS Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spread to cooling tower infill to make sure better cooling effect of the cooling tower.   ABS material sprinkler head could make to max. 4 inches, which is usually used in small (below 100 RT) cooling towers. Below is the detailed specification of the ABS material water distribution head:  Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of ABS Sprinkler Head: Please make sure external thread or internal thread sprinkler head when ordering.
  • NS002 ZM ll Cooling Tower Spray Nozzles-NS002 ZM Cooling Tower plastic spray nozzles -NS002 ZM nozzles are gravity flow and could easily be inspected and replaced while the equipment is in operation. Large orifice make sure non-clogging performance for effective wetting of the heat-transfer surface.  Features •1-5/16'' diameter opening. •EVAPCO’S Zero Maintenance ZM®II Spray Nozzle remains clog-free. •Providing even and constant water distribution for reliable. Detail pictures Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU Payment term: T/T, L/C, West Union Minimum Order Quantity: 100pcs    NEWIN Other Nozzles You may be also interested in below cooling tower spray nozzles, please click the nozzle pictures for more details.             
  • cooling tower fan motor Round type cooling tower fan motor 5.5kw, 1410r/m, 7.5HP, 4P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
  • Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • NS003 Evapco 2A Series Nozzle - NS003 Evapco 2A Series Nozzle - NS003 Features: -Easily removed for cleaning and system maintenance.  -With its robust design elements 2 series nozzles have a well established history of efficient trouble free operation. -Inside diameter: 26mm  Outside diameter: 29mm  (water inlet) Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU Payment term: T/T, L/C, West Union Minimum Order Quantity: 100pcs   Detail pictures NEWIN other nozzles   You may be also interested in below cooling tower spray nozzles, please click the nozzle pictures for more details.          
<< 1 2 3 4 5 6 >>
Copyright © 2019 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show