Contact Us
  • No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Products
  • EVL-2 Cooling tower air inlet louver EVL EVL cooling tower air inlet louver Features ■ Improve air flow into the cooling tower. ■ Prevent debris from entering. ■ Prevent the splash of water droplets. ■ Restrict the amount of sunlight into cooling tower (to impede algae growth). ■ Reduce noise from the tower. ■ Achieves very low pressure drop result. ■ Easy installation and access for cleaning and maintenance. ■ Used in a wide variety of new and retrofit applications, including air inlets for both package     and field-erected counter flow and straight-sided cross flow towers, fresh air make-up systems, air pollution control scrubbers, and VOC strippers. Specification Model--     EVL Length depend on customer demand Width depend on customer demand Thickness 65/75 mm Sheet thickness 0.4 mm Continuous operation temperature PVC --- 50℃ Max. application temp. (short term) PVC --- 60℃ Color  Black,Grey Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs EVL air inlet louver Pictures --- cooling tower air inlet louver You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Counter flow cooling tower fills HAN series 500x1000mm, 610x1000 Cooling Tower Film Fill 500/610x1000mm , 500/610x2000mm , 500/610x3000mm cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 22mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Marley fills MBH Series 800/900/1000/1100/1200 x any length Cooling Tower Filling Dimension: 1220x1854mm; PVC sheet thickness: 0.3-0.5 mm Sheet spacing: 18mm Marley(SPX cooling tower) replacement fills, 3 years quality guarantee. Specification:  Dimension:    1220*1854mm                     1220*2260mm                     1220*2472mm                      1220*any Sheet space: 19mm Sheet thickness: 0.33-0.35mm Applicant: Marley(SPX)cross flow square type(box type) cooling tower
  • NAL-2 Factory price cooling tower PVC air inlet louver NAL NAL cooling tower air inlet louver Air inlet louver are designed to control the loss of water, chemicals, minerals droplets that evaporate into the atmosphere in a cooling tower by capturing and preventing the harmful droplets from evaporating into the environment. Air inlet louver perform their function by causing droplets to switch direction and lose their velocity once they hit the blade walls causing the droplets to fall back into the cooling tower. The most efficient cooling tower louvers will keep your loss of drift to lower than a .001% drift rate.   Features ■ Improve air flow into the cooling tower. ■ Prevent debris from entering and the splash of water droplets. ■ Restrict the amount of sunlight into cooling tower (to impede algae growth). ■ Achieves very low pressure drop result. ■ Easy installation and access for cleaning and maintenance. ■ Reduce noise from the tower.   Specification   Model--NAL PVC Frame PP, aluminium alloy for option Length depend on customer demand Width depend on customer demand Thickness 70 mm Sheet thickness 0.4 mm Continuous operation temperature 50℃ Max. application temp. (short term) 60℃ Color  Black Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing NAL air inlet louver Pictures --- cooling tower air inlet louver PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Kingsun counter flow film fill media Counter Flow Cooling Tower Film Fill Media LAN-19 LAN Cooling Tower Infill is widely used in Liangchi, Kingsun brand counter flow cooling towers. Good ventilation, small resistance, strong hydrophilic, large contact area, and good film-forming, easy packing heat conductivity, good chemical stability, acid, alkali and organic solvent corrosion, etc. The staggered ring material form assembling, packing general is 60 ° Angle, polyvinyl chloride (PVC), 
  • drift eliminator cooling tower Multi Dimensional Cooling Tower Drift Eliminator Multi Dimensional PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Support height: 35 mm, 50 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the Multi dimensional Blade Type Drift Eliminator:   Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN MBD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower. Feaures ■ Made of flame retardant pvc material ■ Anti-aging, low airflow resistance, high strength ■ Optimal droplet capture ■ easy installation and long service life Specification Model--MBD PVC Max.length depend on customer demand Width depend on customer demand Height 150 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, MARLEY TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   MBD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • cooling tower reducer Cooling Tower Belt Reducer At present, the main transmission methods for mechanical draft cooling tower are multi-polar direct drive motor, belt type reduction drive, gear reducer drive, hydraulic turbine drive etc. Belt type reduction drive is widely application, through the tension in the pulley of the driving wheel and driven wheel belt for the power transfer to a mechanical transmission, it has a simple structure, stable transmission, can buffer vibration absorption, can be in large axial spacing between shaft and transmission power, low cost, without lubrication, easy maintenance and other characteristics, widely used in the cooling tower and a number of mechanical equipment.  Below is the Marley cooling tower belt reducer specification.                   
  • Mesan cross flow cooling tower film fill MEH Series 666x1000mm Mesan Cooling Tower Infill Mesan cross flow cooling tower fills. High quality PVC material ensures long service life. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:    666x900mm                    666x1000mm                    666x1230mm Sheet space: 18mm Sheet thickness: 0.33-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type(box type) cooling tower
  • Liangchi Cooling Tower Drift Eliminator Liangchi Cooling Tower Drift Eliminator 50mm NEWIN LAD eliminators LAD-50 is a high efficiency cellular drift eliminator and minimize the water drit emission,easy to handle ,lift and remove for inspection and servicing of water dirtribution system hand heat tranfer surface (fill and coil), apply for Liangchi cooling tower and counter flow cooling tower. Feaures ■ Nested sezm modules ■ Minimal pressure drop ■ Optimal droplet capture ■ Maximum operational safety ■ Long service life Specification Model--LAD PVC Max.length depend on customer demand Width depend on customer demand Height 200 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, LIANGCHI TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   LAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Round Type Cooling Tower Infill Round Type Cooling Tower Infill 300-18 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Evapco fills, Cross flow fills TCH Series 1060 x 885mm Cross Flow infill for Evapco cooling tower Dimension: 1060x885mm Sheet space: 16 mm Sheet thickness: 0.28-0.5 mm (customized thickness accepted)
<< 1 2 3 4 5 6 >>
Copyright © 2019 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show