Contact Us
  • Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Products
  • NAL-2 Factory price cooling tower PVC air inlet louver NAL NAL cooling tower air inlet louver Air inlet louver are designed to control the loss of water, chemicals, minerals droplets that evaporate into the atmosphere in a cooling tower by capturing and preventing the harmful droplets from evaporating into the environment. Air inlet louver perform their function by causing droplets to switch direction and lose their velocity once they hit the blade walls causing the droplets to fall back into the cooling tower. The most efficient cooling tower louvers will keep your loss of drift to lower than a .001% drift rate.   Features ■ Improve air flow into the cooling tower. ■ Prevent debris from entering and the splash of water droplets. ■ Restrict the amount of sunlight into cooling tower (to impede algae growth). ■ Achieves very low pressure drop result. ■ Easy installation and access for cleaning and maintenance. ■ Reduce noise from the tower.   Specification   Model--NAL PVC Frame PP, aluminium alloy for option Length depend on customer demand Width depend on customer demand Thickness 70 mm Sheet thickness 0.4 mm Continuous operation temperature 50℃ Max. application temp. (short term) 60℃ Color  Black Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing NAL air inlet louver Pictures --- cooling tower air inlet louver PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Counter flow cooling tower fills 500x1000mm S Wave Cooling Tower Film Fill 500x1000mm , 500x1080mm cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 25mm / 35mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Round Type Cooling Tower Infill Round Type Cooling Tower Infill 300-18 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • FRP Cooling Tower Fan FRP Cooling Tower Fan Newin cooling tower fans are widely used for bottle type cooling towers, square type cooling towers and industrial cooling towers. The cooling tower fans are made of ABS or Alloy aluminum, Stainless steel 304 or FRP. We also provide customized fan for cooling towers. Welcome to contact us for details if any query.    4.7 Meters FRP cooling tower fan parameters   Fan Model LF47 LF47II LF47III LF47F Fan diameter  (m) 4.7 4.7 4.7 4.7 Impeller speed (r/min) 240 220 238 240 Blade angle 12.5° 12° 19° 12.5° Blade quantity 4 4 4 4 Fan volume (x 104m3/s) 60 60 78 60 Pressure (Pa) 127.5 128.74 137 127.5 Efficiency (%) 83.3 84.9 78.1 83.3 Shaft power (kw) 25.5 25.27 38 25.5 Motor power (kw) 30 30 45 30 Motor speed (r/min) 980 980 1480 980 Motor weight (kg) 292 292 435 292 Weight (without motor) (kg) 547 550 547 547 Imperller axial force (kg) 226 220 239 226 Imperller rotation inertia (kg·m2) 99.88 88.36 99.88 145.96 Max.vibration velocity (mm/s) 6.3 6.3 6.3 6.3 Vibration frequency Motor  (HZ) 16.33 16.33 24.67 16.33 Impeller (HZ) 4 3.7 4 4         Torque Reaction     Motor Normal duty  R4 (kg) 82 82 73 82 Start duty R4 (kg) 410 410 365 410   Gearbox R1 (kg) 310 323 445 290 R2 (kg) 181 189 199 130 R3 (kg) 50 50 38 37     Pictures of FRP cooling tower fans    
  • Round Type Cooling Tower Infill YN-230 Round Type Cooling Tower Infill YN-230 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Blade Type Drift Eliminator NBD-160 Blade Type Cooling Tower Drift Eliminator NBD-160 drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement. 
  • Cooling Tower Gearbox Reducer -- NCJ Series Cooling Tower Gearbox Reducer -- NCJ Series Cooling Tower Gearbox Reducer -- NCJ Series Adopts spiral bevel gear transmission. Through flange cooperation, the motor center and the gear box gear center are exactly the same. The motor directly drives the reducer drive gear without the transmission shaft to transmit the torque. The motor adopts the protection class IP55 and insulation class F for the cooling tower. Products structure is compact. Features - Radically solved the problem of drive shaft failure. - do not have to proofread the drive shaft, the installation is very convenient. - Reduce energy consumption by 5%-10% and reduce vibration by 50%.   Model Description Model Motor Specification Noise Value (JM Distance ) Motor Weight  (KG ) Gear Box  Weight   ( KG ) Reducer  Weight  ( KG ) NCJ 132-4-180 V1  4kw-6(132M1) 67 64 92 156 NCJ 132-4-210 V1  4kw-6(132M1) 67 64 92 156 NCJ 132-4-270 V1  4kw-4(112M)(+) 67 46 92 138 NCJ 132-4-320 V1  4kw-4(112M)(+) 68 46 92 138 NCJ 132-5.5-180 V1  5.5kw-6(132M2) 67 75 92 167 NCJ 132-5.5-210 V1  5.5kw-6(132M2) 67 75 92 167 NCJ 132-5.5-270 V1  5.5kw-4(132S1) 68 59 92 151 NCJ 132-5.5-320 V1  5.5kw-4(132S1) 68 59 92 151 NCJ 132-7.5-270 V1  7.5kw-4(132M) 68 72.5 92 164.5 NCJ 132-7.5-320 V1  7.5kw-4(132M) 68 72.5 92 164.5 NCJ 180-11-165 V1  11kw-6(160L) 67 107 133 240 NCJ 180-11-210 V1  11kw-4(160M) 70 107 133 240 NCJ 180-11-250 V1  11kw-4(160M) 70 107 133 240 NCJ 180-15-165 B35    15KW-6(180L) 67 130 133 263 NCJ 180-15-210 V1  15kw-4(160L) 70 130 133 263 NCJ 180-15-250 V1  15kw-4(160L) 70 130 133 263 NCJ180-18.5-250 B35 18.5KW-4(180M) 70 153 133 286 NCJ180-18.5-210 B35 18.5KW-4(180M) 70 153 133 286 NCJ180-22-210 B35 22KW-4(180L) 70 190/223 133 323/356 NCJ180-22-250 B35 22KW-4(180L) 70 170 133 303 NCJ225-18.5-200 B35 18.5KW-6(200L1) 71 204 218 422 NCJ225-22-160 B35 18.5KW-6(200L1) 71 250 218 468 NCJ225-22-200 B35 22KW-6(200L2) 71 250 218 468 NCJ225-30-160 B35 30KW-6(225M) 71 305 218 523 NCJ225-30-200 B35 30KW-6(225M) 71 305 218 523 NCJ225-30-240 B35 30KW-6(200L) 71 305 218 518 NCJ225-37-160 B35 37KW-6(225L2)# 71 278 218 496 NCJ225-37-200 B35 37KW-6(225L2)# 71 278 218 496 NCJ225-37-240 B35 37KW-4(225S) 73 278 235 513 NCJ225-45-240 B35 45KW-4(225M) 73 511 218 729 NCJ250-37-160 B35 37KW-6(250M) 75 355 389 744 NCJ280-45-160 B35 45KW-6(280S) 75 312 405 717 NCJ280-55-160 B35 55KW-6(280M) 77 582 405 987 NCJ315-75-155 B35 75KW-6(315S) 77 1100 643 1743 NCJ315-90-155 B35 90KW-6(315M) 77 870 643 1513 NCJ315-110-155 B35 110KW-6(315L1) 77 936 643 1579   Installation   Model NCJ132 NCJ180 NCJ225 NCJ280 NCJ315 Size A 16 18 20 24 32 B 31.8 34.4 39.9 50.4 67.4 C 55 60 70 90 120 D 115(1:10) 115(1:10) 115(1:10) 115(1:20) 154(1:20) E 91 126 205 223 245 F 320 360 400 516 560 G 265 300 400 500 600 H ø28/ø38 ø42/ø48 ø55/ø60 ø65/ø75 ø80 I 8/10 12/14 16/18 18/20 22 J 17.3/22.3 24.3/27.8 31.8/34.4 36.9/42.4 45.4 K 14 16 18 18 20 L 300 350 450 550 660 M 230 250 350 450 550 O 16 19 19 22 22 P 220 270 290 349 403 Other types of Gearbox  Click below picture for knowing more details about other series.   
  • SMC FRP Cooling Tower Fan Stack SMC FRP Cooling Tower Fan Stack NEWIN SMC FRP Cooling Tower Fan Stack Features: ■. Molded SMC Fan Stack, beautiful appearance, smooth surface, low wind resistance  ■. Accurate size and good air tightness, Formed under high temperature and high pressure, accurate size and great air tightness. ■. Molded FRP fan stack has a forming pressure of 1200 tons, molding temperature of 150 ° C to make sure high density, high compactness, high strength and low deformation of the products. ■. High production efficiency --- a set of molded mold could produce 3 sets of products per day (3x2x48 pieces) for 9.754meters diameter fan stack ■. Standardized fan stack, easy to install and greatly reduced installation time ■. Environmental Friendly comparing with traditional hand paste fan stacks, protects workers' health and little scraps Structure of the molded SMC Fan stack FRP molded air cylinder is divided into upper and lower parts, 360° is divided into several equal parts and connected by screws. Parameters of NFS series SMC Fan Stack  2.2 m (meters) height SMC fan stack  For Fan Diameter: 4.7m, 5m, 5.5m, 6m  3.0 m (meters) height SMC fan stack   For Fan Diameter: 4.7m, 5m, 5.5m, 6m, 7m, 7.7m, 8m, 8.53m   3.8 m (meters) height SMC fan stack  For Fan Diameter: 7m, 8m, 8.53m, 9.14m, 9.754m, 10.36m   Model H1 (mm) H2 (mm) H3 (mm) Φ (mm) Φ3 (mm) Φ1 (mm) Φ2 (mm) Nos of pcs  per set NFS-4.7-2.2 2200 1200 300 4760 4890 5664 5844 24 NFS-5.0-2.2 2200 1200 300 5060 5190 5964 6144 28 NFS-5.5-2.2 2200 1200 300 5520 5650 6424 6604 28 NFS-6.0-2.2 2200 1200 300 6060 6190 6964 7144 32 NFS-4.7-3.0 3000 1200 300 4760 4998 5664 5844 24 NFS-5.0-3.0 3000 1200 300 5060 5298 5964 6144 28 NFS-5.5-3.0 3000 1200 300 5520 5758 6424 6604 28 NFS-6.0-3.0 3000 1200 300 6060 6298 6964 7144 32 NFS-7.0-3.0 3000 1200 300 7060 7298 7964 8144 36 NFS-7.7-3.0 3000 1200 300 7760 7998 8664 8844 40 NFS-8.0-3.0 3000 1200 300 8070 8308 8974 9154 40 NFS-8.5-3.0 3000 1200 300 8610 8848 9514 9694 44 NFS-7.0-3.8 3800 1650 400 7060 7404 8472 8652 36 NFS-7.7-3.8 3800 1650 400 7760 8104 9172 9352 40 NFS-8.0-3.8 3800 1650 400 8070 8414 9482 9662 40 NFS-8.5-3.8 3800 1650 400 8610 8954 10022 10202 44 NFS-9.14-3.8 3800 1650 400 9220 9564 10632 10812 48 NFS-9.75-3.8 3800 1650 400 9834 10178 11246 11426 48 NFS-10.36-3.8 3800 1650 400 10460 10804 11872 12052 52 Remark: Thickness for upper parts: middle area: 3mm, edge area: 8-12mm                Thickness for lower parts: midd area: 4mm, edge area: 8-12mm Projects of SMC FRP Cooling Tower Fan Stack Manufacturing of SMC FRP Cooling Tower Fan Stack  
  • BAC Cooling Tower Drift Eliminator BAC Cooling Tower Drift Eliminator 120mm NEWIN BAD eliminators BAD drift eliminator efficiently minimize the water drift emission, maximum confidence of the cooling tower. Feaures ■ Maximum drift capture through efficient design ■ Minimal pressure drop ■ Light weight ■ easy cleaning ■ easy installation and long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 120 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, BAC COOLING TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   BAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Counter flow cooling tower fills 500x1000mm Hamon Cooling Tower Film Fill 500x1000mm , 500x2000mm , 500x3000mm cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 22mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Marley fills NAH Series 1220 x any length Cooling Tower Filling Dimension: 1220x1854mm; PVC sheet thickness: 0.3-0.5 mm Sheet spacing: 18mm Marley(SPX cooling tower) replacement fills, 3 years quality guarantee. Specification:  Dimension:    1220*1854mm                     1220*2260mm                     1220*2472mm                      1220*any Sheet space: 19mm Sheet thickness: 0.33-0.35mm Applicant: Marley(SPX)cross flow square type(box type) cooling tower
  • Kingsun counter flow film fill media Counter Flow Cooling Tower Film Fill Media LAN-19 LAN Cooling Tower Infill is widely used in Liangchi, Kingsun brand counter flow cooling towers. Good ventilation, small resistance, strong hydrophilic, large contact area, and good film-forming, easy packing heat conductivity, good chemical stability, acid, alkali and organic solvent corrosion, etc. The staggered ring material form assembling, packing general is 60 ° Angle, polyvinyl chloride (PVC), 
<< 1 2 3 4 5 >>
Copyright © 2019 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show