Contact Us
  • No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Products
  • FRP Cooling Tower Fan FRP Cooling Tower Fan Newin cooling tower fans are widely used for bottle type cooling towers, square type cooling towers and industrial cooling towers. The cooling tower fans are made of ABS or Alloy aluminum, Stainless steel 304 or FRP. We also provide customized fan for cooling towers. Welcome to contact us for details if any query.    4.7 Meters FRP cooling tower fan parameters   Fan Model LF47 LF47II LF47III LF47F Fan diameter  (m) 4.7 4.7 4.7 4.7 Impeller speed (r/min) 240 220 238 240 Blade angle 12.5° 12° 19° 12.5° Blade quantity 4 4 4 4 Fan volume (x 104m3/s) 60 60 78 60 Pressure (Pa) 127.5 128.74 137 127.5 Efficiency (%) 83.3 84.9 78.1 83.3 Shaft power (kw) 25.5 25.27 38 25.5 Motor power (kw) 30 30 45 30 Motor speed (r/min) 980 980 1480 980 Motor weight (kg) 292 292 435 292 Weight (without motor) (kg) 547 550 547 547 Imperller axial force (kg) 226 220 239 226 Imperller rotation inertia (kg·m2) 99.88 88.36 99.88 145.96 Max.vibration velocity (mm/s) 6.3 6.3 6.3 6.3 Vibration frequency Motor  (HZ) 16.33 16.33 24.67 16.33 Impeller (HZ) 4 3.7 4 4         Torque Reaction     Motor Normal duty  R4 (kg) 82 82 73 82 Start duty R4 (kg) 410 410 365 410   Gearbox R1 (kg) 310 323 445 290 R2 (kg) 181 189 199 130 R3 (kg) 50 50 38 37     Pictures of FRP cooling tower fans    
  • Kuken Cooling Tower Fillers KUH Series 750 / 950 x any length Kuken Cooling Tower PVC Fillers KUH Cross Flow Film Fill: Features ■ Hanging design type or glue sticked type are available ■ Sharp horizontal corrugations allow even water redistribution on the sheet and water rotation for good contact with air. The offset flute design allows vertical rotation of air with limited pressure drop. ■ adapted to any induced draft or natural draft cooling tower using normal industrial water quality ■ Well Long service life with minimal maintenance ■ Width with 730mm, 750mm, 950mm, 980mm x any length are available to meet different customers' requirements.     Specification Model--MAH PVC Max.length Depend on customer demand Width 750/950 mm Normal size 750/950 x 1000 mm, 750/950 x 1800 mm, 750/950 x 2000 mm, 750 x any length Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color Black, grey Corrugation height 28 mm Installation method Hung  Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   Structure Drawing KUH Infill Pictures --- cooling tower cross flow film fill PVC Plastic sheet(after molding) Physical and mechanical property  No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-1991 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness  Resistance Temperature ordinary type tb ℃ ≤-8  DL/T 742-2001 Frigostabile type ≤-18 *5 oxygen index OI   -- ≥30 GB/T 2406 1-2008 Cooling tower plastic parts code and standard GB/T 1033-2008 plastic density and relative density experiment method GB/T 2406-2008 plastic combustion performance test method, oxidation index GB/T 13022-1991 plastic film tensile performance test methods GB/T 1190-1991 plastic rectangular tear performance test methods Test report of PVC sheet material You may be also interested in below infill/PVC fills/fillings/water filters, please click the filling pictures for more details.         
  • Liangchi cross flow cooling tower film fill LAH Series 750 x 800mm or 750 x 1600mm Liangchi cross flow film fills Liangchi cross flow cooling tower fills. High quality PVC material ensures long service life. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:     750*800mm                      750*400mm                      750*1600mm                       750*1000mm                       750*1200mm                       750*2000mm Sheet space: 17.5mm Sheet thickness: 0.33-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type(box type) cooling tower
  • Aluminium Alloy Customerization Cooling Tower Fan Aluminium Alloy Customerization Cooling Tower Fan Newin cooling tower fans are widely used for bottle type cooling towers, square type cooling towers and industrial cooling towers. The cooling tower fans are made of ABS or Alloy aluminum, Stainless steel 304 or FRP. We also provide customized fan for cooling towers. Welcome to contact us for details if any query.    Aluminium alloy cooling tower fan parameters   Model       Motor  power Speed Blade  angle Static  pressure Air  Flow Hub  height Bore  dia Key  width Key  depth kw rpm ° Pa m³/h H Φd F T CF1184-4 1.1 720 18 73 28000 63 or 83 28 8 3.3 1.5 21 71 32000 1.5 24 62 36000 CF1500-4 2.2 460 18 70 45000 83 34 8 3.3 21 70 50000 24 65 55000 CF1800-4 4 365 18 66 70000 108 38 8 or 10 3.3 21 69 75000 24 60 85000 CF2000-4 5.5 320 18 75 90000 108 38 8     3.3 21 77 100000 24 70 110000 CF2200-4 5.5 265 18 69 100000 123 50 12     3.3 21 73 105000 24 63 115000 CF2400-4 5.5 250 18 60 130000 123 50 12     3.3 21 61 140000 24 62 150000 CF3000-4 5.5 230 17 70 180000 138 50 12     3.3 11 20 68 200000 11 23 68 220000 CF3400-4 11 200 17 56 240000 148 60 12     3.3 11 20 58 270000 15 23 60 300000 CF3700-4 15 200 16 61 310000 158 75 20     4.9 15 19 65 340000 18.5 22 69 370000 CF3700-4 15 200 16 61 310000 158 75 20     4.9 15 19 65 340000 18.5 22 69 370000 CF4200-4 18.5 175 16 68 400000 158 75 20     4.9 22 19 65 440000 22 22 63 480000 CF5000-4 30 170 14 70 600000 158 75 20     4.9 37 17 76 640000 37 20 82 680000   Pictures of aluminium alloy cooling tower fans    
  • S Shape Blade Type Cooling Tower Drift Eliminator S Shape Blade Type Cooling Tower Drift Eliminator S Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 230 mm Length: customization Width: customization Support height: 45 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the S type Drift Eliminator:       Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                          Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Blade Type Drift Eliminator NBD-160 Blade Type Cooling Tower Drift Eliminator NBD-160 drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement. 
  • BAC Cooling Tower Drift Eliminator BAC Cooling Tower Drift Eliminator 120mm NEWIN BAD eliminators BAD drift eliminator efficiently minimize the water drift emission, maximum confidence of the cooling tower. Feaures ■ Maximum drift capture through efficient design ■ Minimal pressure drop ■ Light weight ■ easy cleaning ■ easy installation and long service life Specification Model--BAD PVC Max.length depend on customer demand Width depend on customer demand Height 120 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, BAC COOLING TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   BAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Cross flow cooling tower fills HOH Series 810/910/1010mm Cross Flow Cooling Tower Film Fill 810/910/1210x any mm , cooling tower fills,  Material: Black PVC Dimension:     810x1250mm                       910x1000any Sheet space: 18 mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Counter flow cooling tower fills NSN series Cooling Tower Counter Flow Film Fill 500x1000mm , cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 30 / 33mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Cooling Tower Aluminum Alloy Sprinkler Head Cooling Tower Aluminum Alloy Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spread to cooling tower infill to make sure better cooling effect of the cooling tower. Using imported bearing, with double bearing design, stable operation and superior performance characteristics, applicable in 8-1000 RT cooling towers. Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT 5" 4 2.5" 100-125 RT 6" 4 3" 150-200 RT 8" 6 3" 225-400 RT 10" 8 3" 500-700 RT 12" 10 3" 800-1000 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of Aluminum alloy Sprinkler Head for different size.                 
  • M Shape Blade Type Cooling Tower Drift Eliminator M Shape Blade Type Cooling Tower Drift Eliminator M Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Drift eliminator piece thickness: 0.8 mm Application: counter flow cooling tower    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the M type Drift Eliminator:           Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                                 Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Square Type Cooling Tower Reducer Pulley Square Type Cooling Tower Reducer Pulley Square Type Cooling Tower Belt Reducer Specification.         Model Nos.of Groove H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T ST-8 4 85 55 420 105 430 580 540 38 4-Ø14 41 8 ST-10 4 85 55 480 117 430 580 540 50 4-Ø14 53 12 ST-12 4 85 205 700 133 608 730 688 50 4-Ø16 53 12 ST-14 5 105 205 700 143 660 765 720 60 4-Ø18 63 12 ST-16 8 165 205 800 153 660 765 720 75 4-Ø18 79.5 20  Remark: Above installation data is only for reference. Customization is acceptable  
<< 1 2 3 4 5 6 >>