Contact Us
  • No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Search
Home >>water-eliminator-filter
  • Counter flow cooling tower fills NSN series Cooling Tower Counter Flow Film Fill 500x1000mm , cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 30 / 33mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Cross flow cooling tower fills DBH Series 500 x 1200mm Cooling Tower PVC Fills 1200x500 mm , cooling tower fills,  Material: Blue PVC Dimension:     1200x500mm                        1200xany Sheet space: 18 mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Cross flow cooling tower fills HOH Series 810/910/1010mm Cross Flow Cooling Tower Film Fill 810/910/1210x any mm , cooling tower fills,  Material: Black PVC Dimension:     810x1250mm                       910x1000any Sheet space: 18 mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Counter flow cooling tower fills HAN series 500x1000mm, 610x1000 Cooling Tower Film Fill 500/610x1000mm , 500/610x2000mm , 500/610x3000mm cooling tower fills,  Material: Black PVC Dimension:     500x1000mm                        500xany Sheet space: 22mm Sheet thickness: 0.25-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: counter flow square type cooling tower, Power plant cooling tower fills, NH3 plant cooling tower fills, Industrial cooling tower fills
  • Counter flow cooling tower fills 230/460/695mm Cooling Tower Film Fill LXN  
  • Cooling Tower Drift Eliminator Cooling Tower Drift Eliminator 200mm NEWIN SMD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and lose velocity at impact on the blade walls and fall back into the tower. Feaures ■ Made of flame retardant pvc material ■ Maximum drife capture through efficient design ■ Anti-aging, low airflow resistance, high strength ■ Optimal droplet capture ■ easy installation and long service life Specification Model--SMD PVC Max.length depend on customer demand Width depend on customer demand Height 200 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application          Counter flow cooling tower, BAC TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing SMD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for old cooling towers as replacement.    
  • Liangchi Cooling Tower Drift Eliminator Liangchi Cooling Tower Drift Eliminator 50mm NEWIN LAD eliminators LAD-50 is a high efficiency cellular drift eliminator and minimize the water drit emission,easy to handle ,lift and remove for inspection and servicing of water dirtribution system hand heat tranfer surface (fill and coil), apply for Liangchi cooling tower and counter flow cooling tower. Feaures ■ Nested sezm modules ■ Minimal pressure drop ■ Optimal droplet capture ■ Maximum operational safety ■ Long service life Specification Model--LAD PVC Max.length depend on customer demand Width depend on customer demand Height 200 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, LIANGCHI TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   LAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • BAC Cooling Tower Drift Eliminator BAC Cooling Tower Drift Eliminator 120mm NEWIN BAD eliminators BAD drift eliminator efficiently minimize the water drift emission, maximum confidence of the cooling tower. Feaures ■ Maximum drift capture through efficient design ■ Minimal pressure drop ■ Light weight ■ easy cleaning ■ easy installation and long service life Specification Model--BAD PVC Max.length depend on customer demand Width depend on customer demand Height 120 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, BAC COOLING TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   BAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Cooling Tower Nylon Sprinkler Head Cooling Tower Nylon Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spread to cooling tower infill to make sure better cooling effect of the cooling tower.   Nylon material sprinkler head could make to max. 4 inches, which is usually used in small (below 100 RT) cooling towers. Below is the detailed specification of the Nylon material water distribution head:  Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of Nylon Sprinkler Head:
<< 1 2
Copyright © 2020 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show