Contact Us
  • No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: No.510, Building 12, Tiedong, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Search
Home >>round-type-cooling-tower-infill
  • Shinwa cooling tower fills SHH Series 950 x 950mm or 950 x 1270mm Shinwa Cooling Tower Infill Dimension: 950 x 950 mm 200 x 950 mm 300 x 950 mm 1270 x 950 mm Sheet space: 20 mm Sheet thickness: 0.28-0.5 mm (customized thickness accepted)                       
  • Spingle Cooling tower cross flow fills SPH Series 850 x 1000 mm or 1000 x 1000mm Spindle Cooling Tower Fills Dimension: 850 x 1000 mm 1000 x 1000 mm 850 x 400 mm 1000 x 1300 mm Sheet space: 18 mm Sheet thickness: 0.28-0.5 mm (customized thickness accepted)                       
  • BAC cross flow cooling tower replacement fills BAH Series 1330 x any length BAC Cooling Tower PVC Fills BAC cooling tower high quality replacement film fills, 3-years quality guarantee. Dimension: 1330 x 2450 mm                        1330 x 2560 mm                          1330 x 2880 mm or any Sheet space: 19 mm Sheet thickness: 0.35-0.4 mm (customized available)     Application: BAC cooling tower 3000 series, 1500 series, closed cooling tower FXV series.  
  • Marley fills MAH Series 1220 x 1854mm Marley Cooling Tower PVC Fills Dimension: 1220x1854mm; PVC sheet thickness: 0.3-0.5 mm Sheet spacing: 18mm Marley(SPX cooling tower) replacement fills, 3 years quality guarantee. Specification:  Dimension:    1220*1854mm                     1220*2260mm                     1220*2472mm                      1220*any Sheet space: 19mm Sheet thickness: 0.33-0.35mm Applicant: Marley(SPX)cross flow square type(box type) cooling tower
  • Kuken Cooling Tower Fillers KUH Series 750 / 950 x any length Kuken Cooling Tower PVC Fillers KUH Cross Flow Film Fill: Features ■ Hanging design type or glue sticked type are available ■ Sharp horizontal corrugations allow even water redistribution on the sheet and water rotation for good contact with air. The offset flute design allows vertical rotation of air with limited pressure drop. ■ adapted to any induced draft or natural draft cooling tower using normal industrial water quality ■ Well Long service life with minimal maintenance ■ Width with 730mm, 750mm, 950mm, 980mm x any length are available to meet different customers' requirements.     Specification Model--MAH PVC Max.length Depend on customer demand Width 750/950 mm Normal size 750/950 x 1000 mm, 750/950 x 1800 mm, 750/950 x 2000 mm, 750 x any length Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color Black, grey Corrugation height 28 mm Installation method Hung  Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   Structure Drawing KUH Infill Pictures --- cooling tower cross flow film fill KUH Cross Flow Cooling Tower Infill Production Process https://youtu.be/OggscZTvf2A PVC Plastic sheet(after molding) Physical and mechanical property  No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-1991 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness  Resistance Temperature ordinary type tb ℃ ≤-8  DL/T 742-2001 Frigostabile type ≤-18 *5 oxygen index OI   -- ≥30 GB/T 2406 1-2008 Cooling tower plastic parts code and standard GB/T 1033-2008 plastic density and relative density experiment method GB/T 2406-2008 plastic combustion performance test method, oxidation index GB/T 13022-1991 plastic film tensile performance test methods GB/T 1190-1991 plastic rectangular tear performance test methods Test report of PVC sheet material You may be also interested in below infill/PVC fills/fillings/water filters, please click the filling pictures for more details.         
  • Kingsun counter flow film fill media Counter Flow Cooling Tower Film Fill Media LAN-19 LAN Cooling Tower Infill is widely used in Liangchi, Kingsun brand counter flow cooling towers. Good ventilation, small resistance, strong hydrophilic, large contact area, and good film-forming, easy packing heat conductivity, good chemical stability, acid, alkali and organic solvent corrosion, etc. The staggered ring material form assembling, packing general is 60 ° Angle, polyvinyl chloride (PVC), 
  • Evapco Brand Cooling Tower Parts Evapco Brand Cooling Tower Parts Kinds of Evapco Brand Cooling Tower Prats, cooling tower fans, cooling tower fills, cooling tower drift eliminators, vibration switch, motor, water distribution system, make-up float valve, pan strainer, louvers, fan motors, fan shaft and bearings, ect.
  • Marley (SPX) Brand Cooling Tower Parts Marley (SPX) Brand Cooling Tower Parts Kinds of Marley Brand Cooling Tower Prats, cooling tower fans, cooling tower fills, cooling tower drift eliminators, cooling tower belt reducer, vibration switch, motor, water distribution system, make-up float valve, pan strainer, louvers, fan motors, fan shaft and bearings, ect.
  • Evapco cooling tower fills Cooling Tower Infill EVN-300 Replacement of Evapco cooling tower infill is specially designed to induce highly turbulent mixing of the air and water for superior heat transfer. The fill is constructed of PVC, will not rot or decay. Because of the unique way in which the cross-fluted sheets are bonded together, and the bottom support of the fill section, the structural integrity of the fills is greatly enhanced, making the fills usable as a working platform.
  • BAC Brand Cooling Tower Parts BAC Brand Cooling Tower Parts Axial Fans 1.Standard fan is high – efficiency and low sound 2.Rugged,aluminum construction for corrosion resistance and extended life 3.Reduced sound levels, Low Sound Fans, Whisper Quiet Fans, and sound attenuation are available. 4.Maintain thermal performance as originally certified by CTI 5.Most fan kits include bushing and special length bolts 6.Available in sizes from 24” to 156” diameter , 4 blades to 12 blades to 12 blades for economical and quiet operation. Centrifugal Fans 1. Low sound 2. Maintain thermal performance as originally certified by CTI 3. Complete installation kit includes hardware , adhesive , and clamps 4. Availability: available in 15” ,18” ,22” ,and 30” diameters for shafts 1-3/16” to 5”in diameter.
  • NAL-2 Factory price cooling tower PVC air inlet louver NAL NAL cooling tower air inlet louver Air inlet louver are designed to control the loss of water, chemicals, minerals droplets that evaporate into the atmosphere in a cooling tower by capturing and preventing the harmful droplets from evaporating into the environment. Air inlet louver perform their function by causing droplets to switch direction and lose their velocity once they hit the blade walls causing the droplets to fall back into the cooling tower. The most efficient cooling tower louvers will keep your loss of drift to lower than a .001% drift rate.   Features ■ Improve air flow into the cooling tower. ■ Prevent debris from entering and the splash of water droplets. ■ Restrict the amount of sunlight into cooling tower (to impede algae growth). ■ Achieves very low pressure drop result. ■ Easy installation and access for cleaning and maintenance. ■ Reduce noise from the tower.   Specification   Model--NAL PVC Frame PP, aluminium alloy for option Length depend on customer demand Width depend on customer demand Thickness 70 mm Sheet thickness 0.4 mm Continuous operation temperature 50℃ Max. application temp. (short term) 60℃ Color  Black Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing NAL air inlet louver Pictures --- cooling tower air inlet louver PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • NS016 ABS plastic spray nozzles for cooling Tower-NS016 Cooling Tower ABS plastic spray nozzles-NS016 Dimension  Model: NSN-2  connection size  DN20 ( 3/4")  25MM  DN25 (1")  32MM  DN32 (1.2")  40MM  DN40 (1.5")  45MM  DN50 (2")  57MM Features: -External screw connection -Excellent insulation -High mechanical strength. -Resistance of pressure and strong wreckage -Excellent resistance of wear -Excellent stability and chemical property -Resistance of high temperature ABS plastic spray nozzles   Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU Payment term: T/T, L/C, West Union Minimum Order Quantity: 100pcs NEWIN other nozzles NEWIN Other Nozzle You may be also interested in below cooling tower spray nozzles, please click the nozzle pictures for more details.         
<< 1 2 3 4 5 6 >>
Copyright © 2020 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show