Contact Us
  • Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Search
Home >>pvc-fills-for-cooling-tower
  • Round Type Cooling Tower Reducer Pulley Round Type Cooling Tower Reducer Pulley Round Type Cooling Tower Reducer Specification.         Model Nos.of Groove H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T RT-5 2 45 50 175 76 355 300 263 34 4-Ø13 37 8 RT-6 3 65 60 225 105 456 348 300 38 4-Ø14 41 8 RT-8 4 85 62 265 120 456 428 390 50 6-Ø16 53 12 RT-10 4 85 62 310 135 608 500 450 50 4-Ø16 53 12 RT-12 5 105 62 310 143 660 500 450 60 4-Ø16 63 12 RT-14 6 125 62 320 153 660 500 450 75 6-Ø16 79.5 20  Remark: Above installation data is only for reference. Customization is acceptable  
  • Square Type Cooling Tower Reducer Pulley Square Type Cooling Tower Reducer Pulley Square Type Cooling Tower Belt Reducer Specification.         Model Nos.of Groove H H1 H2 H3 Ø1 Ø2 Ø3 Ø4 N-ØD K T ST-8 4 85 55 420 105 430 580 540 38 4-Ø14 41 8 ST-10 4 85 55 480 117 430 580 540 50 4-Ø14 53 12 ST-12 4 85 205 700 133 608 730 688 50 4-Ø16 53 12 ST-14 5 105 205 700 143 660 765 720 60 4-Ø18 63 12 ST-16 8 165 205 800 153 660 765 720 75 4-Ø18 79.5 20  Remark: Above installation data is only for reference. Customization is acceptable  
  • cooling tower reducer Cooling Tower Belt Reducer At present, the main transmission methods for mechanical draft cooling tower are multi-polar direct drive motor, belt type reduction drive, gear reducer drive, hydraulic turbine drive etc. Belt type reduction drive is widely application, through the tension in the pulley of the driving wheel and driven wheel belt for the power transfer to a mechanical transmission, it has a simple structure, stable transmission, can buffer vibration absorption, can be in large axial spacing between shaft and transmission power, low cost, without lubrication, easy maintenance and other characteristics, widely used in the cooling tower and a number of mechanical equipment.  Below is the Marley cooling tower belt reducer specification.                   
  • Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Mesh Specification: Size: 1800 x 1000 mm or 1600 x 1000 mm (Customization is acceptable) Thickness: 0.6-0.8 mm Wire diameter: 0.5 mm PVC material      Air inlet screen assembly       Air inlet louver sheet picture You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN MBD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower. Feaures ■ Made of flame retardant pvc material ■ Anti-aging, low airflow resistance, high strength ■ Optimal droplet capture ■ easy installation and long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 150 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, MARLEY TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   MBD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Blade Type Drift Eliminator NBD-160 Blade Type Cooling Tower Drift Eliminator NBD-160 drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement. 
  • Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN MAD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower. MAD-130 is a high efficiency cellular drift eliminator for counter-flow cooling tower and cross flow cooling tower. It is manufactured from rigid, corrugated PVC sheets resistant to UV, rot, fungi, bacteria, organic/inorganic solvents, acids, alkalis, and chemicals normally found in cooling tower waters. Feaures ■ High temperature (up to 80 ºC) and UV-resistant ■ Minimal pressure drop ■ Optimal droplet capture ■ easy installation and long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 145 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application            Counter flow & Cross flow cooling tower Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   MAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • M Shape Blade Type Cooling Tower Drift Eliminator M Shape Blade Type Cooling Tower Drift Eliminator M Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Drift eliminator piece thickness: 0.8 mm Application: counter flow cooling tower    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the M type Drift Eliminator:           Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                                 Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • S Shape Blade Type Cooling Tower Drift Eliminator S Shape Blade Type Cooling Tower Drift Eliminator S Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 230 mm Length: customization Width: customization Support height: 45 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the S type Drift Eliminator:       Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                          Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Round Type Cooling Tower Infill YN-230 Round Type Cooling Tower Infill YN-230 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • cooling tower fan motor Round type cooling tower fan motor 0.37kw 910r/m 1/2HP, 6P Cooling tower motor is a series specific motor that developed for NEWIN NRT series round type cooling tower, Its insulation class F, IP55 protection grade, ensures the continuous working under high temperature and high humidity environment.
1 2 3 4 5 >>
Copyright © 2019 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show