  • Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Screen Cooling Tower Air Inlet Mesh Specification: Size: 1800 x 1000 mm or 1600 x 1000 mm (Customization is acceptable) Thickness: 0.6-0.8 mm Wire diameter: 0.5 mm PVC material      Air inlet screen assembly       Air inlet louver sheet picture You may be also interested in below PVC Air Inlet Louver/Cooling Tower Air Intake Louver/Cooling Tower Louver/Cooling Tower Air Inlet Louver, please click the filling pictures for more details.     
  • Blade Type Drift Eliminator NBD-160 Blade Type Cooling Tower Drift Eliminator NBD-160 drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement. 
  • M Shape Blade Type Cooling Tower Drift Eliminator M Shape Blade Type Cooling Tower Drift Eliminator M Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Drift eliminator piece thickness: 0.8 mm Application: counter flow cooling tower    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the M type Drift Eliminator:           Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                                 Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • S Shape Blade Type Cooling Tower Drift Eliminator S Shape Blade Type Cooling Tower Drift Eliminator S Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 230 mm Length: customization Width: customization Support height: 45 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the S type Drift Eliminator:       Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                          Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill YN-300 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Cooling Tower ABS Sprinkler Head Cooling Tower ABS Sprinkler Head Cooling tower sprinkler head is an important part of counter-flow round cooling tower water distribution system, it is located the overhead of cooling tower packing, connects the hose of the center water pipe and the cooling tower distribution pipes. Its role is to make water evenly spread to cooling tower infill to make sure better cooling effect of the cooling tower.   ABS material sprinkler head could make to max. 4 inches, which is usually used in small (below 100 RT) cooling towers. Below is the detailed specification of the ABS material water distribution head:  Head size Nos. of holes Hole size Cooling tower 1.5" 4 1/2" 8-10 RT 2" 4 3/4" 15-20 RT 3" 4  1.5" 25-50 RT 4" 6 1.5" 60-80 RT Note: 3" head 6 holes and 4" head 4 holes are available.   Pictures of ABS Sprinkler Head: Please make sure external thread or internal thread sprinkler head when ordering.
  • drift eliminator cooling tower Multi Dimensional Cooling Tower Drift Eliminator Multi Dimensional PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Support height: 35 mm, 50 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the Multi dimensional Blade Type Drift Eliminator:   Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Round Type Cooling Tower Infill Round Type Cooling Tower Infill 300-18 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Round Type Cooling Tower Infill Round Type Cooling Tower Infill 240-13 Round Type Cooling Tower Infill, a type of corrugated PVC film fill, which is special design for counter flow round type cooling tower. It is most popular heat-eliminating medium for round type cooling tower. This type of infill made flame retardant PVC material, Thermal formed by mold, the corrugated shape greatly increase the cooling area and greatly lengthen the time water keep on the surface of infill. The adoption of round type cooling tower infill makes round type cooling tower performance better and take smaller space.
  • Liangchi cross flow cooling tower film fill LAH Series 750 x 800mm or 750 x 1600mm Liangchi cross flow film fills Liangchi cross flow cooling tower fills. High quality PVC material ensures long service life. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:     750*800mm                      750*400mm                      750*1600mm                       750*1000mm                       750*1200mm                       750*2000mm Sheet space: 17.5mm Sheet thickness: 0.33-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type(box type) cooling tower
  • Shinwa cooling tower fills SHH Series 950 x 950mm or 950 x 1270mm Shinwa Cooling Tower Infill Dimension: 950 x 950 mm 200 x 950 mm 300 x 950 mm 1270 x 950 mm Sheet space: 20 mm Sheet thickness: 0.28-0.5 mm (customized thickness accepted)                       
  • Spingle Cooling tower cross flow fills SPH Series 850 x 1000 mm or 1000 x 1000mm Spindle Cooling Tower Fills Dimension: 850 x 1000 mm 1000 x 1000 mm 850 x 400 mm 1000 x 1300 mm Sheet space: 18 mm Sheet thickness: 0.28-0.5 mm (customized thickness accepted)                       