Contact Us
  • Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

    Add: Trade Plaza No.5, China South City, Pinghu Street, Longgang District, Shenzhen, China.

  • Tel: 0086 755 23077266

  • sales@newinmachine.com

    Email: sales@newinmachine.com

  • newin109

    Skype: newin109

Search
Home >>drift-eliminator-manufacturer
  • Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN MBD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower. Feaures ■ Made of flame retardant pvc material ■ Anti-aging, low airflow resistance, high strength ■ Optimal droplet capture ■ easy installation and long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 150 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application       Counter flow cooling tower, MARLEY TOWER Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   MBD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Evapco Cooling Tower Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN EVD eliminators Drift eliminators remove small droplets of water that are entrained in the exhaust air to minimize the nuisance and health issues that they create if allowed to escape through the top of the tower along with the heated air. Drift eliminators are designed to create a tortuous path for the air stream. When the water droplets move through them, they are forced to change direction and impact the drift eliminator side walls, coalescing and draining back into the wet section of the cooling tower. The drift eliminators are constructed of an inert polyvinyl chloride (PVC) plastic material which effectively eliminates corrosion of these vital components. They are assembled in sections to facilitate easy removal for inspection of the water distribution system. Feaures ■ Anti-aging, high water absorption ■ low airflow resistance, high strength ■ easy installation and long service life ■ can be the replacement of air inlet louver Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 145 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application                    Counter flow cooling tower Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs Structure Drawing NVD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • Blade Type Drift Eliminator NBD-160 Blade Type Cooling Tower Drift Eliminator NBD-160 drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement. 
  • Drift Eliminator Newin Cooling Tower Drift Eliminator NEWIN MAD eliminators Drift eliminators are designed to capture large water droplets caught in the cooling tower air stream.The eliminators prevent the water droplets and mist from escaping the cooling tower.Eliminators do this by causing the droplets to change direction and losr velocity at impact on the blade walls and fall back into the tower. MAD-130 is a high efficiency cellular drift eliminator for counter-flow cooling tower and cross flow cooling tower. It is manufactured from rigid, corrugated PVC sheets resistant to UV, rot, fungi, bacteria, organic/inorganic solvents, acids, alkalis, and chemicals normally found in cooling tower waters. Feaures ■ High temperature (up to 80 ºC) and UV-resistant ■ Minimal pressure drop ■ Optimal droplet capture ■ easy installation and long service life Specification Model--NVD PVC Max.length depend on customer demand Width depend on customer demand Height 145 mm Continuous operation tempperature 50℃ Max.applicationtemp. (short term) 60℃ Color  Black Application            Counter flow & Cross flow cooling tower Packing and Loading:  LCL shipment: by plywood pallet/case/carton, FCL shipment: by container Trade Terms: EXW, FOB, CFR,CIF, DDU. Payment term: T/T, L/C, West Union Minimum Order Quantity: 1000pcs   MAD drift eliminator Pictures --- cooling tower drift eliminator  PVC Plastic sheet(after molding) Physical and mechanical property No. Item symbol unit index test method 1 density ρ g/cm3 ≤1.55 GB/T 1033 1-2008 2 tensile strength lengthways σt MPa ≥42.0 GB/T 13022-91 crosswise ≥38.0 3 tear strength lengthways σtr kN/m ≥150 GB/T 1130-91 crosswise ≥160 4 Folded in half Coldness Resistance Temperature ordinary type tb ℃ ≤-8 DL/T 742-2001 Frigostabile type ≤-18 5 oxygen index OI -- ≥30 GB/T 2406 1-2008 Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers  which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.    
  • M Shape Blade Type Cooling Tower Drift Eliminator M Shape Blade Type Cooling Tower Drift Eliminator M Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Drift eliminator piece thickness: 0.8 mm Application: counter flow cooling tower    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the M type Drift Eliminator:           Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                                 Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • S Shape Blade Type Cooling Tower Drift Eliminator S Shape Blade Type Cooling Tower Drift Eliminator S Type PVC Cooling Tower Drift Eliminator   Basic data: Height: 230 mm Length: customization Width: customization Support height: 45 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the S type Drift Eliminator:       Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                          Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • drift eliminator cooling tower Multi Dimensional Cooling Tower Drift Eliminator Multi Dimensional PVC Cooling Tower Drift Eliminator   Basic data: Height: 175 mm Length: customization Width: customization Support height: 35 mm, 50 mm Drift eliminator piece thickness: 0.8 mm    PVC Cooling tower drift eliminator material physical and mechanical properties:  No.  Item  Unit  Index Test Method   1  Density  g/cm3  ≤1.6  GB/T 1033  2  Dimensional stability  %  ≤5    3  Tensile strength   Mpa  ≥45  GB/T 13022  4  Elongation at break  %  ≥40  GB/T 13022  5  Izod impact strength  102KJ/m  before aging≥45,  after aging  ≥36  GB/T 1843  6  Vicat softening point  ℃  ≥82  GB/T 1633  7  Oxygen index  %  ≥40  GB/T 2406   Cooling tower drift eliminator spare parts specification and mechanical properties:   No. Name Specification (mm) Material Rupture tension 1 bar Ø8 PVC ≥10×103 2 support  According to drift eliminator type ABS / PP ≥2.5×102 3 locating ring Ø10×45 PVC   4 nut M8 PVC Detailed pictures of the Multi dimensional Blade Type Drift Eliminator:   Replacement for other brand cooling towers: Our drift eliminators are modular PVC drift eliminators that most of modern cooling towers such Marley, Evapco, BAC, etc, which are easily re-fitted with our new PVC drift eliminators.They are perfect for older cooling towers as replacement.                Delivery time: We will deliver your new drift eliminators in 1-6 weeks, depending on the total of drift eliminators you require. Warranty: All our drift eliminators are under 1 year warranty when deliver from our factory.
  • Liangchi cross flow cooling tower film fill LAH Series 750 x 800mm or 750 x 1600mm Liangchi cross flow film fills Liangchi cross flow cooling tower fills. High quality PVC material ensures long service life. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:     750*800mm                      750*400mm                      750*1600mm                       750*1000mm                       750*1200mm                       750*2000mm Sheet space: 17.5mm Sheet thickness: 0.33-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type(box type) cooling tower
  • Evapco Brand Cooling Tower Parts Evapco Brand Cooling Tower Parts Kinds of Evapco Brand Cooling Tower Prats, cooling tower fans, cooling tower fills, cooling tower drift eliminators, vibration switch, motor, water distribution system, make-up float valve, pan strainer, louvers, fan motors, fan shaft and bearings, ect.
  • Marley (SPX) Brand Cooling Tower Parts Marley (SPX) Brand Cooling Tower Parts Kinds of Marley Brand Cooling Tower Prats, cooling tower fans, cooling tower fills, cooling tower drift eliminators, cooling tower belt reducer, vibration switch, motor, water distribution system, make-up float valve, pan strainer, louvers, fan motors, fan shaft and bearings, ect.
  • Marley cooling tower drift eliminator, cooling tower pvc drift eliminator NVD 130mm Drift Eliminator for Marley cooling tower NVD 130mm Drift Eliminator for Marley cooling tower        Dimension: 130 mm         Material: pvc         width: any width          length: any length                       
  • Mesan cross flow cooling tower film fill MEH Series 666x1000mm Mesan Cooling Tower Infill Mesan cross flow cooling tower fills. High quality PVC material ensures long service life. Features: light weight, strength, good flame retardant performance, corrosion resistance, advanced design, ventilation resistance is small, strong hydrophilicity, large contact area, etc Specification:  Dimension:    666x900mm                    666x1000mm                    666x1230mm Sheet space: 18mm Sheet thickness: 0.33-0.35mm Applicable water temperature: 75℃ ~ -35℃ Applicant: cross flow square type(box type) cooling tower
1 2 >>
Copyright © 2019 Shenzhen Newin Machinery Co., Ltd. All rights reserved. Powered by
hide show